Product Name : ACRC502
Item# : 20431-109
Model : 20431-109
Was Price: CNY0/pc
Now Price : CNY0/pc
Last update : 2016.12.31
Manufacturer :
More Picture:

InRow RC, 600mm, Chilled Water, 380-415V, 50Hz

Includes: Installation guide , Operations and maintenance manual

 

InRow Chilled Water CoolingFeatures & Benefits

Manageability
  • Building management system integration
    Send alarms and data points allowing you to manage critical building infrastructure from a single system.
  • Microprocessor controller
    Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.
  • Real-Time Capacity Monitoring
    Real-time display of current and available cooling.
Agility
  • Casters
    Provides flexibility to move the unit to wherever cooling is required.
  • Scaleable densities
    Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.
  • Modular design
    Modular design provides scalable solutions to add cooling as demand increases.
Serviceability
  • Easy service access
    Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
Availability
  • Active response controls
    Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
  • Top and bottom chilled water connections
    Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.
  • Rack inlet control
    Rack inlet control guarantees inlet temperature to IT equipment.
  • Dual A-B power inputs
    Draws power from the UPS for power protection with dual feeds for redundancy.
  • Predictable cooling
    Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
Total Cost of Ownership
  • Row-based architecture
    Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
  • Variable speed fans
    Variable speed fans reduce energy consumption during off-peak cooling periods.

    Input

    • Nominal Input Voltage
      400V 3PH
    • Input frequency
      50/60 Hz
    • Input Connections
      IEC 309 16A 3P+N+PE
    • Number of Power Cords
      2

    Communications & Management

    • Control panel
      Multi-function LCD status and control console
    • Audible Alarm
      Audible and visible alarms prioritized by severity

    Physical

    • Maximum Height
      1991mm , 199.1cm
    • Maximum Width
      600mm , 60.0cm
    • Maximum Depth
      1070mm , 107.0cm
    • Rack Height
      42U
    • Net Weight
      345.45kg
    • Shipping weight
      405.45kg
    • Shipping Height
      2166mm , 216.6cm
    • Shipping Width
      850mm , 85.0cm
    • Shipping Depth
      1137mm , 113.7cm
    • Color
      Black
    • Units per Pallet
      1.0

    Conformance

    • Approvals
      cUL Listed, CE, Industry Canada, UL Listed, VDE
    • Standard warranty
      1 year (parts only), 1 year on-site repair or replace with factory authorized Start-Up

    General

    • Air Discharge Patterns
      Horizontal
    • Air Flow
      2831.68lps
    • Condensate Pump Capacity
      0.008lps
    • Intake Air
      Rear Return
    • Minimum Water Inlet Temperature
      7.0 °C

 