Rack PDU, Switched, 1U, 16A, 208/230V, (8)C13

Includes: Installation Guide , Rack Mounting Brackets , User Manual

 

Switched Rack PDUFeatures & Benefits

Marketing Features
  • Power Delays
    Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.
  • Remote Individual Outlet Control
    Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).
  • Remote Management Capabilities
    Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
  • Local Current Monitoring Display
    The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.
  • Alarm Thresholds
    Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
 
Availability
  • Power Delays
    Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.
  • Network Management Capabilities
    Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
  • Local Current Monitoring Display
    The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)
  • Remote Individual Outlet Control
    Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).
  • Alarm Thresholds
    Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)
  • Integrates with StruxureWare Data Center Expert
    An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
  • Flash Upgradeable
    Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
  • Load indicator LED
    Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.
 
Agility
  • Rack-Mountable
    Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
  • Wide range of input and output connections
    Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.
  • Single input power source
    Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.

    Output

    • Nominal Output Voltage
      208V , 230V
    • Maximum Total Current Draw
      16
    • Output Connections
      (8) IEC 320 C13 (Battery Backup)                                                                                                 

    Input

    • Nominal Input Voltage
      200V , 208V , 230V
    • Input frequency
      50/60 Hz
    • Input Connections
      IEC-320 C20
    • Cord Length
      2.5meters
    • Acceptable Input Voltage
      200-240VAC
    • Number of Power Cords
      1
    • Load Capacity
      3680VA
    • Maximum Input Current
      20A
    • Regulatory Derated Input Current (North America)
      16A

    Physical

    • Maximum Height
      44mm , 4.4cm
    • Maximum Width
      445mm , 44.5cm
    • Maximum Depth
      108mm , 10.8cm
    • Rack Height
      1U
    • Net Weight
      2.27kg
    • Shipping weight
      3.45kg
    • Shipping Height
      70mm , 7.0cm
    • Shipping Width
      470mm , 47.0cm
    • Shipping Depth
      343mm , 34.3cm
    • Color
      Black

    Environmental

    • Operating Environment
      0 - 45 °C
    • Operating Relative Humidity
      0 - 95 %
    • Operating Elevation
      0-3000meters
    • Storage Temperature
      -25 - 65 °C
    • Storage Relative Humidity
      0 - 95 %
    • Storage Elevation
      0-15000meters

    Conformance

    • Approvals
      cUL Listed, CE, CSA, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, IRAM, MIC, UL 60950, UL Listed, VDE, VCCI
    • Standard warranty
      2 years repair or replace

    Sustainable Offer Status

    • RoHS
      Compliant
    • REACH
      REACH: Contains No SVHCs
    • Battery Directive
      Compliant
    • Battery Notes
      ts_Battery_Notes

 

| Clicks:

Online Server

Salesperson①
Salesperson②
Salesperson③
Engineer
Customer service